UPC 723834656556
Barcode for (KAS) Electric Heat Sequencer Control DPST 24 Volt for Q103 24A34-3 1056789 1256504
Scannable Barcode for UPC 723834656556
Sellers
Marketplace | Price | Updated |
---|---|---|
$26.13 | 09/26/2018 04:38:03 GMT - Details |
Recently Searched
UPC 786710004636
Emerson 24A34-3 Electric Heat Sequencer, 2 Switches
Best Price: $8.85
View Product
UPC 786710004667
Emerson 24A34-6 Electric Heat Sequencer, 4 Switches
Best Price: $19.14
View Product
Attributes
Attribute | Value |
---|---|
EAN | 0723834656556 |
UPC | 723834656556 |
Brand | KAS |
Label | KAS |
Studio | KAS |
Binding | Misc. |
Publisher | KAS |
Manufacturer | KAS |
Product Group | Home Improvement |
Product Features
- Replacement for Numbers: Carrier HN67QC005, ICP (Heil, Comfortmaker, Tempstar, Arcoair) 1056789, HQ1056789, Diversitech DGS103, Goodman / Amana / Janitrol 1256504 BT1256504, Klixon E017, Mars 33244, 33844, Napco NS103, Supco Q103, White Rodgers 24A34-3. Watsco TDR20, York 525-37322-000.
- PSQ Models are Direct Replacement for Most Fan / Heat Sequencing Functions
- Terminal Markings are Equivalent to Competitive Types
- Parts Connect Sequencer part number PCQ103
- 24 Volts, DPST, 1 Timing / 2 Switch, Off 40-110 Seconds, On 1-20 Seconds
Description
Replacement for Numbers: Carrier HN67QC005, ICP (Heil, Comfortmaker, Tempstar, Arcoair) 1056789, HQ1056789, Diversitech DGS103, Goodman / Amana / Janitrol 1256504 BT1256504, Klixon E017, Mars 33244, 33844, Napco NS103, Supco Q103, White Rodgers 24A34-3. Watsco TDR20, York 525-37322-000. COMBINED LOAD RATING TABLE (ALL MODELS) 30A @ 240 VAC TOTAL, 23A Non-Inductive + 7 FLA / 42 LRA Inductive, ON Time: Elapsed time to make contacts after heater is energized (min. to max.) OFF Time: Elapsed time to break contacts after heater is de-energized (min. to max.) M1-M2 and M3-M4 are always first switches to turn ON and last to turn OFF. All other switches are random ON and random OFF NOTE : Underwriters Laboratories requires a fan interlock circuit to insure the blower remains operating whenever more than one sequencer is used. The fan interlock should be the M1/ M2 contacts of the second or third sequencer. All M1/ M2 contacts are wired to the blower motor so that any sequencer that is energized will keep the blower ON.
Price Disclaimer
Product prices are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on amazon.com, amazonsupply.com, or myhabit.com at the time of purchase will apply to the purchase of this product.