Barcode for Dixell XR30CX-5N1C1 Digital Thermostat Controller Off Cycle Defrost AUX Relay 230V/50Hz-60Hz Programmable-Commercial for Refrigeration

Scannable Barcode for UPC 791974135200

scannable barcode image

Sellers

Marketplace Price Updated
$87.99 07/03/2023 23:04:54 GMT - Details

Recently Searched

UPC 024847592269

Generac 197279GS Control Board Genuine Original Equipment Manufacturer Part

Best Price: $260.95 View Product

UPC 768488579851

WS2812B WS2811 WS2815 SK6812 SP107E Smart Music Bluetooth Full Color Controller iOS/Andriod App Control Support Almost All The LED IC Chip Suit for LED Strip, Matrix Panel, DC5-24V

Best Price: $21.90 View Product

Attributes

Attribute Value
Brand Dixell
Color Gray
EAN 0791974135200
MPN Dixell-0120
UPC 791974135200

Description

  1. It is a digital thermostat with off cycle defrost designed for refrigeration applications at normal temperature. It provides two relay outputs, one for the compressor, the other one can be used as light, for alarm signalling or as auxiliary output.
  2. The regulation is performed according to the temperature measured by the thermostat probe with a positive differential from the set point: if the temperature increases and reaches set point plus differential the compressor is started and then turned off when the temperature reaches the set point value again. In case of fault in the thermostat probe the start and stop of the compressor are timed through parameters COn and COF.
  3. Defrost is performed through a simple stop of the compressor. Parameter IdF controls the interval between defrost cycles, while its length is controlled by parameter MdF.Case, XR30CX frontal 32x74 mm; depth 60mm;
  4. SAFETY PRECAUTIONS Check the supply voltage is correct before connecting the instrument. Do not expose to water or moisture: use the controller only within the operating limits avoiding sudden temperature changes with high atmospheric humidity to prevent formation of condensation. Warning: disconnect all electrical connections before any kind of maintenance. Fit the probe where it is not accessible by the End User. The instrument must not be opened.
  5. In case of failure or faulty operation send the instrument back to the distributor or to Dixell S.r.l. with a detailed description of the fault. Consider the maximum current which can be applied to each relay . Ensure that the wires for probes, loads and the power supply are separated and far enough from each other, without crossing or intertwining.