upc 791974322471 image

UPC 791974322471

Barcode for Dixell XR06CX-4N1F1 110V/50-60Hz Adjustable Digital Thermostat Controller Compressor Defrost Fans with Temperature Probes for Refrigerating Units

Scannable Barcode for UPC 791974322471

scannable barcode image

Sellers

Marketplace Price Updated
$53.95 12/28/2023 15:14:08 GMT - Details

Recently Searched

UPC 197644780860

Dixell Temperature Controller XR02CX - 120V - Programmable - Commercial Refrigeration - ONLY for REFRIGERATORS

Best Price: $119.00 View Product

UPC 811374035310

Bucked Up Energy Drink 300mg

Best Price: $29.77 View Product

Attributes

Attribute Value
Brand LSBYLM
EAN 0791974322471
Manufacturer LSBYLM
MPN Dixell-Jason2023000178
UPC 791974322471

Description

  1. XR06CX is for applications on medium or low temperature ventilated refrigerating units.With FC parameter it can be selected the fans functioning FC cn will switch ON and OFF with the compressor and not run during defrost FC on fans will run even if the compressor is off, and not run during defrost After defrost, there is a timed fan delay allowing for drip time, set by means of the Fd parameter.
  2. FC cy fans will switch ON and OFF with the compressor and run during defrost FC oY fans will run continuously also during defrost. An additional parameter FS provides the setting of temperature, detected by the evaporator probe, above which the fans are always OFF. This is used to make sure circulation of air only if his temperature is lower than set in FS.
  3. FANS AND DIGITAL INPUT When the digital input is configured as door switch iF do, fans and compressor status depends on the dC parameter value: dC no normal regulation; dC Fn fans OFF; dC cP compressor OFF; dC Fc compressor and fans OFF. When rd y, the regulation restart with door open alarm
  4. SAFETY PRECAUTIONS Check the supply voltage is correct before connecting the instrument. Do not expose to water or moisture: use the controller only within the operating limits avoiding sudden temperature changes with high atmospheric humidity to prevent formation of condensation. Warning: disconnect all electrical connections before any kind of maintenance.
  5. Fit the probe where it is not accessible by the End User. The instrument must not be opened. In case of failure or faulty operation send the instrument back to the distributor or to Dixell S.r.l. with a detailed description of the fault. Consider the maximum current which can be applied to each relay .

Reviews

Be the first to write a review.

Searching: