Scannable Barcode for UPC 716709390242
Sellers
Marketplace | Price | Updated |
---|---|---|
$107.99 | 07/03/2023 23:04:54 GMT - Details |
Recently Searched
UPC 791974135200
Dixell XR30CX-5N1C1 Digital Thermostat Controller Off Cycle Defrost AUX Relay 230V/50Hz-60Hz Programmable-Commercial for Refrigeration
Best Price: $87.99
View Product
UPC 024847592269
Generac 197279GS Control Board Genuine Original Equipment Manufacturer Part
Best Price: $260.95
View Product
Attributes
Attribute | Value |
---|---|
Binding | Misc. |
Brand | LSBYLM |
EAN | 0716709390242 |
Manufacturer | LSBYLM |
MPN | Dixell-Jason202303020002 |
UPC | 716709390242 |
Description
- COMPRESSOR:The regulation is performed according to the temperature measured by the thermostat probe with a positive differential from the set point: if the temperature increases and reaches set point plus differential the compressor is started and then turned off when the temperature reaches the set point value again. In case of fault in the thermostat probe the start and stop of the compressor are timed through parameters COn" and COF .
- DEFROST:Two defrost modes are available through the tdF" parameter: defrost through electrical heater and hot gas defrost . Other parameters are used to control the interval between defrost cycles , its maximum length and two defrost modes: timed or controlled by the evaporator's probe .At the end of defrost dripping time is started, its length is set in the FSt parameter. With FSt 0 the dripping time is disabled.
- CONTROL OF EVAPORATOR FANS:The fan control mode is selected by means of the FnC" parameter: FnC C_n: fans will switch ON and OFF with the compressor and not run during defrost FnC o_n fans will run even if the compressor is off, and not run during defrost; After defrost, there is a timed fan delay allowing for drip time, set by means of the Fnd" parameter. FnC C_Y fans will switch ON and OFF with the compressor and run during defrost;
- An additional parameter FSt" provides the setting of temperature, detected by the evaporator probe, above which the fans are always OFF. This is used to make sure circulation of air only if his temperature is lower than set in FSt".
- Forced activation of fans:This function managed by the Fct parameter is designed to avoid short cycles of fans, that could happen when the controller is switched on or after a defrost, when the room air warms the evaporator. Functioning: if the difference of temperature between the evaporator and the room probes is more than the value of the Fct parameter, the fans are switched on. With Fct 0 the function is disabled.
- Cyclical activation of the fans with compressor off. When Fnc c-n or c-Y , by means of the Fon and FoF parameters the fans can carry out on and off cycles even if the compressor is switched off. When the compressor is stopped the fans go on working for the Fon time. With Fon 0 the fans remain always off, when the compressor is off.
Price Disclaimer
Product prices are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on amazon.com, amazonsupply.com, or myhabit.com at the time of purchase will apply to the purchase of this product.